China SF6 Gas Analyzer manufacturers

0 votos
1  Optional reference leak detection source.
2. 18 levels of leakage level alarms for three colors and six segments are displayed.
3. Battery test function with accurate voltage display device.
4. Alarm muted.
5. Precise mechanical pump to allow forward air flow through the sensor head.
6. Touch reset button and touch keyboard control.
7. 14 "(35.5mm) bendable stainless steel probe.
The working temperature of SF6 gas qualitative leak detector is 0 to 52 ℃.
Preheating time: about 2 seconds; reset time: 1 second.
Response time: instantaneous.
Sensitivity: less than 14 g / year, minimum 11 g / year, limit sensitivity 2.8 g / year.
Mode of operation: light touch key control, provide 7 levels of sensitivity, real-time sensitivity adjustment.
Work cycle: continuous.
Probe length: 35.5cm.
Power supply: 2 C alkaline batteries; battery life: continuous working for 40 hours, 3V DC, two C # alkaline batteries.
Weight: 560g ABS plastic suitcase.
Maximum sensitivity according to SAEJ1627 verification criterion: the guaranteed value for R12, R22 and R134A is 14 g / year.
Limit sensitivity for SF6 and all halogen-based refrigerants <3 g / year.
The normal life of the battery is about 30 hours.
Load cycle continuous, unlimited.
Device size 22.9Cm × 6.5Cm × 6.5Cm.
2. Optional reference leak detection source.
3. 18 levels of leakage level alarms for three colors and six segments are displayed.
If the sensitivity of the fourth and seventh steps is adjusted, the sensitivity can be increased to 64 times.
5. Battery test function with accurate voltage display device.
6. Alarm muted.
7. Precise mechanical pumps allow forward air to pass through the sensor head.
8. Touch reset button and touch keyboard control.
9, 14 "(35.5mm) bendable stainless steel probe.
Operating temperature: 0 to 52 ℃.
Preheating time: about 2 seconds; reset time: 1 second.
Response time: instantaneous.
Sensitivity: less than 14 g / year, minimum 11 g / year, limit sensitivity 2.8 g / year.
Mode of operation: light touch key control, provide 7 levels of sensitivity, real-time sensitivity adjustment.
Work cycle: continuous.
Probe length: 35.5cm.
Power supply: 2 C alkaline batteries; battery life: continuous working for 40 hours, 3V DC, two C # alkaline batteries.
Weight: 560g ABS plastic suitcase.
Maximum sensitivity according to SAEJ1627 verification criterion: the guaranteed value for R12, R22 and R134A is 14 g / year.
Limit sensitivity for SF6 and all halogen-based refrigerants <3 g / year.
The normal life of the battery is about 30 hours.
Load cycle continuous, unlimited.
Device size 22.9Cm × 6.5Cm × 6.5CmChina SF6 Gas Analyzer manufacturers
website:http://www.bdlangxun.com/sf6-gas-analyzer/
preguntado por koifu77 (280 puntos) Jul 20

Preguntas relacionadas

0 votos
0 respuestas
preguntado por guying (260 puntos) Ene 7
0 votos
0 respuestas
preguntado por oksof48 (300 puntos) Jul 30
0 votos
0 respuestas
preguntado por jsofdv9 (280 puntos) Abr 27
0 votos
0 respuestas
preguntado por kodisd5 (300 puntos) Mar 23
0 votos
0 respuestas
preguntado por kodisd5 (300 puntos) Mar 23
FranciaViajes.com
es donde puedes hacer preguntas y recibir respuestas de otros miembros de la comunidad.

Redes sociales

...